Introduction to products
PRODUCT NAME SLTB05-2 Oil Tube Coatings
BRIEF Two pack of Epoxy - phenolic resin type coating paint
FEATURES
The substrate of processed with excellent adhesion, good abrasion resistance sex, excellent resistance to impact can be used for exposure to air and submerged in the water under the condition of the coating systems.
RESISTANCE GUIDE
HEAT RESISTANCE The highest resistance to 125 ℃ hot and humid alternate, in mud recycling circumstances, can withstand any drilling temperature.
WEATHERABILITY Long-term exposure to the sun may appear a little pulverization or become yellow, but it will not reduce the protective coating
SOLVENTS Resistant to most hydrocarbon solvents, of refined petroleum products overflow and splashes
CHEMICAL RESISTANCE Resists alkali, salt water dilute resistance of liquid to spatter and overflow, performance preferred
CORROSION Resistance to grind loss, improve fluid efficiency, fully after curing wearability.
USES:Widely used in the oil field drill pipe, sucker rod surface corrosion and coating.
TYPICAL PROPERTIES AND APPLICATION DATA
COLOR Black
DENSITY 1.3g/ cm3
SOLIDS BY VOLUME 41%
SPREADING RATE 7.5m2/kg(100umDFT)
REFERENCE THICKNESS 125-225um
DRYING TIME(23℃) Touch 0.5 Hr Handle 24 Hr
OVERCOAT INTERVAL(23℃) Min 8 Hr Max 7 Days
STORAGE(dry, cool ) At least 12 months
FLASH POINT 26℃
PACKAGING Part A: 22kg per barrel
Part B.2: kg per barrel
MIXING RATIO (m/m) Part A:PartB=20:1
CURE TIME(23℃) 10min
POT LIFE(23℃) 4 Hr
DIRECTIONS Stir Part A thoroughly, then mix Part B and stir contents of each till cure time with a broad flat stirrer using a stirring, lifting action or use a power mixer, stir and mix part C slowly. Silicone Thinner X-8 can be added due to application conditions. Rate of cure will vary depending on temperature and other factors such as ventilation, film thickness, humidity, thinner. The temperature of stir will >15℃, otherwise thinner should be added for needed viscosity after stir.
Overmuch thinner will lead sag and slow cure rate, thin film. Practical spreading rates may be reduced 5—25% for wastage of different application conditions.
APPLICATION STEEL: Round off all rough welds, sharp edges and remove weld spatter. Remove grease, oil and other contaminants. Steel surface must be prepared by abrasive blast cleaning to ISO Standard Class Sa3.
Don’t apply at temperatures below 5℃ or above 40℃. Don’t apply at relative humidity above 85% or when the surface is less than 3℃ above the dew point.
Don’t apply if there is fog, rain, snow or strong wind.
BRUSH/ROLLER: Suitable for small areas only. Apply even coats of the mixed material to the prepared surface. Thin if necessary with up to 0-2% with Special Thinner X-2. Additional coats may be required to attain specified thickness.
CONVENTIONAL SPRAY: Thinning is not normally required, however 0-2% of Special Thinner X-2 can be added.
AIRLESS SPRAY: Thinning is not normally required, however 0-2% of Special Thinner X-2 can be added. Pump ratio is 23:1 or 32:1 and fluid tip is 0.38-0.43 mm.
Overcoating: Aged coating should be tested for lifting by a method such as ‘X’cut or crosshatch methods. If it lifts, remove it. The surface must be free of oil, grease and other contaminants.
CLEAN UP: with Special Thinner X-2
SAFETY:Pay attention to the safety precautions before and after using this product. Users should comply with the provision of the respective country or local government. It’s dangerous or deadly to eating it. To avoid inhalation of thinner steams and spray mists.
Use protective wears correctly; the skin and eyes should avoid contacting it. Use with good ventilation. This product is flammable. All sources of ignition must be eliminated in, or near the working area. DO NOT SMOKE. Fight fire with foam, CO2 or dry chemical powder. On burning will emit toxic fumes.
Notes: The data in the manual is get from standard experiments and may be vary from different conditions in use. Please refer to the latest manual if the data is altered and we would not inform specially.