Introduction to products
PRODUCT NAME SLC06 Alkyd Anti-rust Coatings
BRIEF One Pack Alkyd Iron Red Anti-rust Coating
FEATURES
-Excellent adhesion on steel.
-Good anti-rust property.
RESISTANCE GUIDE
HEAT RESISTANCE Up to 80℃ dry heat
WEATHERABILITY Good
SOLVENTS Resists solvents such as alcohol, mineral oil.
ACIDS Do not recommend for contact with splash and spillage of acids fog and solution.
ALKALIS Do not recommend for contact with splash and spillage of alkalis fog and solution.
SALTS Do not recommend for contact with salts solution.
WATER Resist rain and vapor, not suitable for long-term immersion and humidity
ABRASION Good when fully cured.
USES:Used in common anticorrosive conditions of steel.
TYPICAL PROPERTIES AND APPLICATION DATA
COLOR Bulletin color
DENSITY 1.3Kg/L
SOLIDS BY VOLUME 40%
SPREADING RATE 4.7 m2/kg 6.1m2/L (65um DFT)
DRYING TIME(23℃) Touch ≤8 Hr Handle ≤24 Hr Full cure 7Days
OVERCOAT INTERVAL(23℃) 24 Hr
STORAGE (dry, cool ) At least 12 months
PACKAGING 20kg 15.4L
DIRECTIONS Stir contents of each can thoroughly with a broad flat stirrer using a stirring, lifting action or use a power mixer. Rate of cure will vary depending on temperature and other factors such as ventilation, film thickness, humidity, thinner. The temperature of stir will >15℃, otherwise thinner should be added for needed viscosity after stir.
Overmuch thinner will lead sag and slow cure rate, thin film. Practical spreading rates may be reduced 5—80% for wastage of different application conditions.
APPLICATION STEEL: Round off all rough welds, sharp edges and remove weld spatter. Remove grease, oil and other contaminants. Steel surface must be prepared by abrasive blast cleaning to ISO Standard Class Sa2.5 or power tool cleaning Class St3.
Don’t apply at air temperature below 5℃ or above 40℃. Don’t apply at relative humidity above 85% or when air temperature is less than 3℃ above the dew point.
Don’t apply if there is fog, rain, snow or strong wind.
BRUSH/ROLLER: Suitable for small areas only. Apply even coats of the mixed material to the prepared surface. Thin if necessary with up to 0-15% with Alkyd Thinner X-1. Additional coats may be required to attain specified thickness.
CONVENTIONAL SPRAY: Thinning is not normally required, however 0-15% of Alkyd Thinner X-1 can be added.
AIRLESS SPRAY: Thinning is not normally required, however 0-15% of Alkyd Thinner X-1 can be added. Pump ratio is 23:1 or 32:1 and fluid tip is 0.38-0.43 mm.
Overcoating: Aged coating should be tested for lifting by a method such as ‘X’cut or crosshatch methods. If it lifts, remove it. The surface must be free of oil, grease and other contaminants.
CLEAN UP: with Alkyd Thinner X-1
SAFETY :Pay attention to the safety precautions before and after using this product. Users should comply with the provision of the respective country or local government. It’s dangerous or deadly to eating it. To avoid inhalation of thinner steams and spray mists. Use protective wears correctly; the skin and eyes should avoid contacting it. Use with good ventilation. This product is flammable. All sources of ignition must be eliminated in, or near the working area. DO NOT SMOKE. Fight fire with foam, CO2 or dry chemical powder. On burning will emit toxic fumes.