Introduction to products
PRODUCT NAME SLC03 Alkyd Anticorrosive Paint
BRIEF One Pack paint made from alkyd, modifier,pigments and extenders
FEATURES
-Excellent adhesion on steel and wood substrates
-Suitable for exterior and interior exposure
-Good weather ability
-Not suitable for immersion in water or continuous splash of water
-Excellent color retention
RESISTANCE GUIDE
HEAT RESISTANCE Up to 80℃ dry heat
WEATHERABILITY Well
SOLVENTS Resists solvents such as alcohol, mineral oil, and other solvents.
ACIDS Do not recommend for contacting with splash and spillage of acids fog and solution.
ALKALIS Do not recommend for contacting with splash and spillage of alkalis fog and solution.
SALTS Do not recommend for contacting with most salts solution.
WATER Resist rain and vapor, not suitable for long-term immersion and humidity
ABRASION Good when fully cured.
USES:Widely used on surface of metal and wood, industrial and civil facilities.
TYPICAL PROPERTIES AND APPLICATION DATA
COLOR Colors
DENSITY 1.3g/cm3
SOLIDS BY VOLUME 45%
SOLIDS BY WEIGHT 72%
SPREADING RATE 8.6 m2/kg (40um DFT)
DRYING TIME(23℃) Touch 5 Hr Handle 24 Hr
OVERCOAT INTERVAL(23℃) Min 24Hr
STORAGE at least 12 months (dry, cool and under cover )
PACKAGING 20kg
DIRECTIONS Before using stir or using dynamic mixer mixing two components completely. Rate of cure will vary depending on temperature and other factors such as ventilation, film thickness, humidity, thinner. The temperature of stir will >15℃, otherwise thinner should be added for needed viscosity after stir. Overmuch thinner will lead sag and slow cure rate, thin film, thinner should beadded after mixed. Practical spreading rates may be reduced 5%—25% for wastage of different application conditions.
APPLICATION
STEEL: The surface coated by primer or intermediate paint should be dry and clean, no oil and other pollutants. When overcoat on a two-component film such as epoxy paint,wharf's pavement quality for old film should be taken if more than the longest accordance with time.
Don’t apply at temperatures below 5℃ or above 40℃. Don’t apply at relative
humidity above 85% or when the surface is less than 3℃ above the dew point.
Don’t apply if there is fog, rain, snow or strong wind.
BRUSH/ROLLER: Suitable for small areas only. Apply even coats of the mixed material to the prepared surface. Thin if necessary with up to 0-15% with Alkyd Thinner X-1. Additional coats may be required to attain specified thickness.
CONVENTIONAL SPRAY: Thinning is not normally required, however 0-15% of Alkyd Thinner X-1 can be added.
AIRLESS SPRAY: Thinning is not normally required, however 0-5% of Alkyd Thinner X-1 can be added. Pump ratio is 23:1 or 32:1 and fluid tip is 0.38-0.43 mm.
Overcoating: Aged coating should be tested for lifting by a method such as ‘X’cut or crosshatch methods. If it lifts, remove it. The surface must be free of oil, grease and other contaminants.
Previous coat: Epoxy Coatings, Alkyd Primer
CLEAN UP: with Alkyd Thinner X-1
SAFETY:Pay attention to the safety precautions before and after using this product. Users should comply with the provision of the respective country or local government. It’s dangerous or deadly to eating it. To avoid inhalation of thinner steams and spray mists.
Use protective wears correctly; the skin and eyes should avoid contacting it. Use with good ventilation. This product is flammable. All sources of ignition must be eliminated in, or near the working area. DO NOT SMOKE. Fight fire with foam, CO2 or dry chemical powder. On burning will emit toxic fumes.
Notes: The data in the manual is get from standard experiments and may be vary from different conditions in use. Please refer to the latest manual if the data is altered and we would not inform specially.