Introduction to products
PRODUCT NAME SLVEGF -01,02 Epoxy Vinyl Ester Glass-flake Paint
BRIEF Two Pack Paint made from epoxy vinyl ester resin, surface treatment agent,thixotropic agent, glass flake, anticorrosion paint, curing agent, etc
FEATURES
-Excellent abrasion and temperature change resistance,
-Excellent resistance to medium permeability
-Excellent corrosion of acid, alkali, salt and organic matter
-With a good bonding effect of matrix, and the thermal expansion coefficient is small
RESISTANCE GUIDE
HEAT RESISTANCE Up to 90℃ wet heat,180℃ dry heat
ACIDS Suitable for splash and spillage to acids
ALKALIS Suitable for splash and spillage to alkalis
SALTS Excellent resistance to neutral and alkali salts
WATER Excellent resistance to fresh and salt water
ABRASION Good when fully cured.
USES: Widely used inside of the desulfurization equipment of petroleum and petrochemical, thermoelectric, non-ferrous metallurgy, papermaking, chemical industry, etc, and on areas of corrosion is not too serious or inconvenience luting, can also be used for chemical storage tank lining, acid and alkali water tank, storage tank wall of the pool.
TYPICAL PROPERTIES AND APPLICATION DATA
COLOR Primer Topcoat(Colors or According to the customers)
DENSITY 1.3g/cm3
SPREADING RATE 4.5 m2/kg (80um DFT)
DRYING TIME(23℃) Touch 8 Hr Handle 24 Hr Full cure 7Days
OVERCOAT INTERVAL(23℃) Min 8 Hr Max 7 Days
STORAGE Summer 3 months /Winter 3 months (dry, cool and under cover )
PACKAGING Part A: 25kg
MIXING RATIO (m/m) Part A : Part B=25:0.3(0.2~0.3)
CURE TIME(23℃) 10min
POT LIFE(23℃) 1 Hr
DIRECTIONS Before using stir or using dynamic mixer mixing two components completely. Rate of cure will vary depending on temperature and other factors such as ventilation, film thickness, humidity, thinner. The temperature of stir will >15℃, otherwise thinner should be added for needed viscosity after stir. Overmuch thinner will lead sag and slow cure rate, thin film, thinner should be added after mixed. Practical spreading rates may be reduced 5%—25% for wastage of different application conditions.
APPLICATION
STEEL: Steel surface must be prepared by abrasive blast cleaning to ISO Standard Class Sa2.5 or power tool cleaning Class St3. The surface coated by shop primer
should be dry, clean and no dirt, take the second descaling where film damaged
or corrosion, and achieve Sa2.5 level or St3 level. Clear the zinc salt with high
pressure fresh water or sand. Weld and the damage parts processing to Sa2.5 level or
St3 level.
Don’t apply at temperatures below 5℃ or above 40℃. Don’t apply at relative humidity above 85% or when the surface is less than 3℃ above the dew point.
Don’t apply if there is fog, rain, snow or strong wind.
BRUSH/ROLLER: Suitable for small areas only. Apply even coats of the mixed material to the prepared surface. Thin if necessary with up to 0-15% with Special Thinner X-12. Additional coats may be required to attain specified thickness.
CONVENTIONAL SPRAY: Thinning is not normally required, however 0-15% of Special Thinner X-12 can be added.
AIRLESS SPRAY: Thinning is not normally required, however 0-5% of Special Thinner X-12 can be added. Pump ratio is 23:1 or 32:1 and fluid tip is 0.38-0.43 mm.
Overcoating: Aged coating should be tested for lifting by a method such as ‘X’cut or crosshatch methods. If it lifts, remove it. The surface must be free of oil, grease and other contaminants.
CLEAN UP: with Epoxy Thinner X-12
SAFETY:Pay attention to the safety precautions before and after using this product. Users should comply with the provision of the respective country or local government. It’s dangerous or deadly to eating it. To avoid inhalation of thinner steams and spray mists.
Use protective wears correctly; the skin and eyes should avoid contacting it. Use with good ventilation. This product is flammable. All sources of ignition must be eliminated in, or near the working area. DO NOT SMOKE. Fight fire with foam, CO2 or dry chemical powder. On burning will emit toxic fumes.
Notes: The data in the manual is get from standard experiments and may be vary from different conditions in use. Please refer to the latest manual if the data is altered and we would not inform specially.